Fire Test under Positive Pressure UL 10-C


3-sided galvannealed frames




Description
180 minutes
90 minutes
45 minutes
20 minutes

Standard Profile
SR and DR series
16- and 14-gauge
(0.056"/1.4 mm
0.071"/1.8 mm)
8'0" x 8'0"
(2.4 m x 2.4 m)
8'0" x 10'0"
(2.4 m x 3.0 m)
8'0" x 10'0"
(2.4 m x 3.0 m)
8'0" x 10'0"
(2.4 m x 3.0m)

Double egress profile
SR series, welded
16- and 14-gauge
(0.056"/1.4 mm
0.071"/1.8 mm)
Not tested
8'0" x 10'0"
(2.4 m x 3.0 m)
8'0" x 10'0"
(2.4 m x 3.0 m)
8'0" x 10'0"
(2.4 m x 3.0m)

Less retrun frame
LR series
16-gauge
(0.056"/1.4 mm)
Not tested
4'0" x 8'0"
(1.2 m x 2.4 m)
4'0" x 8'0"
(1.2 m x 2.4 m)
4'0" x 8'0"
(1.2 m x 2.4m)





Limitations:

1) Label A frames must be welded.
2) Minimum jamb depth: 3 1/4" (83 mm).
3) Maximum jamb depth: 14 1/2" (368 mm).

Please do not hesitate to contact us for more detailed information on our fire-rated products in stainless steel. We consistently test new products at our testing facility.