Fire Test under Positive Pressure UL 10-C

Galvanealed elevations with intumescent glazing tape (wired glass and ceramic glass)

Transom lights, side lights and borrowed lights
Standard profile, SR and DR series
16-gauge (0.056"/1.4 mm), welded


The following chart contain the maximum dimensions. Only tested for 20 minutes and 45 minutes.



Description
45 minutes
20 minutes

Unit size in drywall partition (WxH)
12'8" x 11'4"
(3.9 m x 3.5 m)
12'8" x 11'4"
(3.9 m x 3.5 m)

Unit size in masonry partition (WxH)
13'6" x 12'0"
(4.1 m x 3.7 m)
13'6" x 12'0"
(4.1 m x 3.7 m)

Exposed glass
4704 in2 (3 m2)
4704 in2 (3 m2)

Exposed glass per lite
4704 in2 (3 m2)
4704 in2 (3 m2)

Maximum width of exposed glass
106" (2.7 m)
106" (2.7 m)

Maximum height of exposed glass
106" (2.7 m)
106" (2.7 m)

Please review the following limitations.



Limitations:


1) Listed glazing products: Wired Glass (Pilkington, Asahi, Central Glass) and Ceramic Glass (firelite). www.fireglass.com
2) Listed intumescent glazing tape: Pemko www.pemko.com
3) Glass thickness: 1/4" (6 mm).
4) Jamb depth: 5 3/4" (146 mm).
5) Maximum face dimension: 4" (102 mm).
6) Maximum sill dimension: 8" (203 mm).
7) Stop height dimension: 5/8" (16 mm).
8) For transom lites and sidelites, respect door opening size limitations
9) Please verify this information with your glass manufacturer.



Please do not hesitate to contact us for more detailed information and to obtain information on our fire rated products in stainless steel.  We consistently test new products at our testing facility.